FIAlyzer-1000
Flow Injection Analysis System
 
»çÀÌÁî 24 cm (h) x 24 cm (d) x 16.5 cm (w)
¹«   °Ô 6.75 kg
Á¦Á¶»ç Fialab Instrument
¿ø»êÁö ¹Ì±¹
     
 
  • There is no need to purchase separate expensive manifolds for each type of analytical method.
  • Wavelength selections are made through software with no additional fibers or lamps required.
  • Monitoring multiple wavelengths (up to 4) extends the system's dynamic range.
  • Reference wavelengths are utilized for compensation of colored matrices and index of refraction effects.
  • The FIA-LAB-2500 automatically corrects for response drift.

Assay Throughput Working Range
Nitrate 180 samples/hour 0.03 mg - 200 mg/liter
Nitrite 220 samples/hour 0.005 mg - 100 mg/liter
Ammonia 120 samples/hour 0.5 mg - 200 mg/liter
Phosphate 120 samples/hour 0.1 mg - 25 mg/liter
Chloride 120 samples/hour 1.0 mg - 50 mg/liter
Iron 140 samples/hour 0.1 ppm - 100 ppm
Specifications
Accuracy (typical) 2% - 3%
Precision (typical) 1% - 2%
Pump 4-channel standard, 6-channel available
ÀϹÝÀûÀÎ ±¸¼º
FIAlab-2500 Automated flow injection analysis system. Four channel (six channel available) peristaltic pump, six port, two position injector valve, fittings and tubing kit, sample loop, operation and experiments manuals. FIAlab for Windows software.
FIA-Lab-On-Valve Integrated manifold which mounts directly on the injection valve,
and includes integrated flow cell.
P600-20 SMA-terminated 600 micron fiber optic cables
USB4000 S4000 spectrometer with USB interface, set to measure wavelengths between 350 to 1000 nm (software selectable).
Also available for 200 to 850 nm ranges, please inquire.
LS-1 Tungsten halogen light source for ~360 nm to 2 mm
wavelength range
Accessories
Dual-FC Dual Flowcells for extended dynamic range. Simultaneous use of a 1 cm and 10 cm flowcell, in series, offers a significantly increased dynamic range. Uses a dual channel spectrometer. Other flowcell length combinations can be used, please inquire.
SCSP-2500 Auto Dilutor - No need to prepare multiple standards, let the SCSP-2500 dilutor prepare the standards automatically. The SCSP-2500 aspirates standards and samples from autosampler, delivers the resulting sample? to the FIAlab-2500, filling the sample loop to? the desired dilution level.?? Accurate dilutions up to twenty fold. Easily create calibration curves from a single standard.
RQV The new Rapid Queuing Valve option allows assays of phosphate and ammonia to be performed at around nine seconds per sample with no loss of accuracy or sensitivity. Some limitations do apply, for instance the RQV is not compatible with the SCSP-2500 autodilutor option. Please inquire for additional information to see if the Rapid Queuing Valve will work with your specific application(s).
FTHEAT Flow through heater required for elevated temperature assays such as Ammonia. Temperature control from ambient up to 50 C. Accuracy is +/- 0.5 C. Coil is made from Teflon tubing 0.03 ID, total coil volume is approximately 700 microliters (other sizes available).
Flow Cells Flowcells from 1 mm to 10 cm optical path lengths
AS-VALVE Automatic Shutdown Valve. At method completion, the AS-VALVE dual 3-way valve switches to rinse position for automatic removal of reagent(s) from manifold.
PMT-FL Photomultiplier Based Flow Through Fluorometer
Misc. Lamps UV and Visible light sources
AIM500 Digestion System for Kjeldahl Nitrogen (TKN) assays of environmental, plant, and food samples
 
 
 
 
 
07072 ¼­¿ï½Ã µ¿ÀÛ±¸ ½Å´ë¹æ1°¡±æ 38 (½Å´ë¹æ 719¹øÁö µ¿Àۻ󶼺ô) 106µ¿ 209È£ (ÁÖ)¿ø¿ì½Ã½ºÅÛÁî
TEL : 02-533-6720  FAX : 02-533-9614
Santevill 106-209, 38, Sindaebang1ga-gil, Dongjak, Seoul, 07072, South Korea
Copyright 2000-2023 Wonwoo Systems Co.,Ltd. All right reserved